Image Medical Equipment Digital X-ray radiography system HD13-DRPS

Changchun Better Biological Technology Co., Ltd

Image Medical Equipment Digital X-ray radiography system HD13-DRPS

Brand Name : dotop
Model Number : HD13-DRPS
Place of Origin : CN
MOQ : 1 set
Price : USD$70,000.00/set
Supply Ability : 20 sets/year
Delivery Time : 30 work dyas
Packaging Details : wooden box
Power : 50KW High frequency high voltage
X tube : High quality
Flat detector : 14 bit
Contact Now

Specifications

Digital photography X-Ray system
Applied to the chest, skull, spine and limbs of the X-ray digital image

Parts

1.High frequency and high voltage generator;
2.X-Ray original parts;
3.Beam limit device;
4.High-voltage cable;
5.Photographing bed;
6.Motor-driven suspension photographing shelf;
7.CCD image detector;
8.Image-processing system;
9.Grid;
10.High voltage cable

1.8 Work Conditions

1.8.1 Environment Condition

a.Environment temperature(10~35)°C;
b.Comparative humidity≤35%~75%;
c.Atmospheric pressure(70~106)KPA .

1.8.2 Power Condition

a.The power voltage of high frequency and high voltage generator is three-phase380V, 50Hz. The permitted change scope of power voltage is 380V±38V, the permitted change scope of the frequency value is 50Hz±1Hz.The power of photographing is with single-phase , 220V±22V, 50Hz±1Hz;
b.Power internal resistance: AC380V power, should be no more than 0.17Ω;
c.Input power: 32 kVA;
d.Power capacity: ≥35 kVA.

1.9 Technique Target and Parameter

1.9.1 Power

a.Maximal output power: 20kW(100kV, 200mA);
b.Nominal electric power: 20kW(100kV, 200mA, 0.1s).

When the maximal kilovolt (KV) is 150KV, the maximal milliampere is 125mA; when the maximal milliamphere is 200mA, the maximal kilovolt (KV) is 100KV.


1.9.2 X-Ray Tube Voltage

a.Take type E7843X, type RAD-14 X-Ray tube voltage adjustment as step-type recording, adjustment scope is(40~150)kV, each grade 1kV;
b.Take type E7242X X-Ray tube voltage adjustment as step-type recording, adjustment scope is 40~125)kV, each grade 1kV;
c.The deviation of X-Ray tube voltage value should be no more than 10%.

Storage and Transportation

a.Environment temperature 15º~35º;
b.Comparative humidity 45%~75%;
c.Atmosphere pressure 86 KPA~106 KPA;
d.Storage and transportation requests of detector: environment temperature scope: -20ºC~55ºC;comparative humidity scope:≤93%;atmosphere pressure scope:50KPA~106KPA.


China Customized Inflatable Bumper Ball Game Bubble Adult Grass CE supplier

Image Medical Equipment Digital X-ray radiography system HD13-DRPS Images

Inquiry Cart 0
Send your message to this supplier
 
From:
Enter your email please.
To: Changchun Better Biological Technology Co., Ltd
Subject:
Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0